Steam header belongs to the category of pressure vessel, its pressure capacity, volume should be corresponding to the supporting boiler. The main compression elements are head, housing, etc.
Boiler Manifold Headers,Oil Boiler Parts ,Boiler Steam Header,Gas Boiler Parts Jinan Yuanda Power Equipment Co.,Ltd. , https://www.ydpowerequipment.com
Description :
The Gathering marine incinerator, which is designed for on board incineration of ship's waste oil and solid, it mainly consists of four parts:Â
A. Combustion chamber with diesel oil burner, sludge burner, and electric control panel.Â
B. Flue gas fanÂ
C. Flue gas damper.Â
D. Sludge tank with circulating pump and heater.Â
Details:Â
The incinerator is equipped with single door in front, which are intended for loadingÂ
Of solid waste and ash removing, the incinerator in stand-by mode(COM. Tem. Less than 220° C), the doors can be opened properly. If the incinerator is running in cooling down mode, the door can be opened till COM. Tem. Less than 100° C and incinerator fully stop.Â
The electrical control panel is installed on the incinerator and it contains fuses, starters, PLC andÂ
Operator panel. The electric panel is built according to international standards for marine equipment.Â
The operator panel which is located at the right side of the control panel has a touch screen andÂ
Defined keys for system starting/stopping and selecting burner modes. The burning process is controlled by the PLC and monitored by the HMI(human machine interface)and scanned by a photo resistor. The combustion chamber temperatures are also regulated automatically by the PLC control system.
Technical Data:
TypeHYÂ INC-18
Â
Capacity
180,000Â kcal/h (Â 208KW)
22.5Â kg/h IMO sludge oil
14,4000Kcal/h solid wasteIMO sludge (20% water content) IMO class 02 solid waste
Combustion chamber temperature
Max.          1180 8C Working       850-1150 8 C
Â
Flue gas temperature
Max.           375 8C Working        250-340 8 C
Â
Surface temperature
Less than ambient temperature +20 8 C , and less than 60°C
Â
Electrical power Consumption
7kW
Â
Negative pressure
5-35 mm WC
Negative pressure in combustion chamber
Total weight
1500 kg
Â
Outline dimension
Â
See dimension drawing (APPENDIX)
Â
Â
Boiler Steam header is the main supporting equipment of the boiler to distribute the steam generated by the boiler operation to various pipelines, it also serves as a reservoir that feeds steam to the individual heating circuits. The boiler steam header must be large enough to virtually eliminate pressure drop between the boiler and the beginning of the circuit.
Marine Incinerator / Solid Waste Incinerator
Model NO.: GRINC-18
Working Temperature: 850~1150
Negative Pressure: 5-35 mm Wc
Electrical Power: 7kw
Total Weight: 1500kg
Certificate: Uscg/CCS/RS
Warranty: 3 Years
Trademark: Gathering
Transport Package: Standard Package
Specification: 180000Kcal/H, 22.5kg/h
Origin: China
HS Code: 8417809090